串聯諧振試驗裝置試驗常見(jian)問題及解決方法
串聯諧振試驗裝置是利用(yong)調(diao)(diao)諧(xie)電(dian)(dian)感與負荷(he)電(dian)(dian)容(rong)使(shi)之產生工頻(pin)串(chuan)聯(lian)諧(xie)振(zhen)(zhen),以獲得工頻(pin)試驗電(dian)(dian)壓(ya)(ya)(ya)的(de)串(chuan)聯(lian)諧(xie)振(zhen)(zhen)試驗裝(zhuang)置。串(chuan)聯(lian)諧(xie)振(zhen)(zhen)由隔離變壓(ya)(ya)(ya)器(qi)(qi)、調(diao)(diao)頻(pin)調(diao)(diao)壓(ya)(ya)(ya)電(dian)(dian)源、激(ji)勵(li)(li)變壓(ya)(ya)(ya)器(qi)(qi)、電(dian)(dian)抗器(qi)(qi)和電(dian)(dian)容(rong)分壓(ya)(ya)(ya)器(qi)(qi)組成。被試品(pin)的(de)電(dian)(dian)容(rong)與電(dian)(dian)抗器(qi)(qi)構成串(chuan)聯(lian)諧(xie)振(zhen)(zhen)連接方式(shi);分壓(ya)(ya)(ya)器(qi)(qi)并聯(lian)在被試品(pin)上,用(yong)于測量被試品(pin)上的(de)諧(xie)振(zhen)(zhen)電(dian)(dian)壓(ya)(ya)(ya),并作過壓(ya)(ya)(ya)保護(hu)信號;調(diao)(diao)頻(pin)功率輸出經激(ji)勵(li)(li)變壓(ya)(ya)(ya)器(qi)(qi)耦合給串(chuan)聯(lian)諧(xie)振(zhen)(zhen)回路,提供串(chuan)聯(lian)諧(xie)振(zhen)(zhen)的(de)激(ji)勵(li)(li)功率。
1、變頻(pin)源主機(ji)找不到諧振(zhen)點(dian)。
2、變頻源主機復位。
3、裝(zhuang)置(zhi)Q值偏低,即電壓升(sheng)不上(shang)去,或升(sheng)不高。
4、供(gong)電電源跳閘。
串聯諧振試驗裝置的構成及特點
串聯諧振試驗(yan)裝置(zhi)是運用串聯諧(xie)(xie)振(zhen)(zhen)原理,使回(hui)路產生(sheng)諧(xie)(xie)振(zhen)(zhen)電(dian)(dian)壓(ya)(ya)加(jia)到試(shi)品(pin)上,串聯諧(xie)(xie)振(zhen)(zhen)裝置目前(qian)分為變(bian)(bian)頻式和調感式兩(liang)大類。串聯諧(xie)(xie)振(zhen)(zhen)裝置主(zhu)要由變(bian)(bian)頻源(yuan)(變(bian)(bian)頻式)、高壓(ya)(ya)電(dian)(dian)抗器(qi)(qi)、可調式電(dian)(dian)抗器(qi)(qi)(調感式)、電(dian)(dian)容(rong)分壓(ya)(ya)器(qi)(qi)、激勵變(bian)(bian)壓(ya)(ya)器(qi)(qi)等(deng)幾部(bu)分組成。廣泛(fan)用于電(dian)(dian)力(li)(li)電(dian)(dian)纜、電(dian)(dian)力(li)(li)變(bian)(bian)壓(ya)(ya)器(qi)(qi)、水力(li)(li)發電(dian)(dian)機、GIS等(deng)大容(rong)量(liang),高電(dian)(dian)壓(ya)(ya)的(de)電(dian)(dian)容(rong)性(xing)試(shi)品(pin)的(de)交(jiao)接和預防(fang)性(xing)試(shi)驗!串聯諧(xie)(xie)振(zhen)(zhen)裝置具有需求電(dian)(dian)源(yuan)容(rong)量(liang)小(xiao)、設(she)備(bei)重量(liang)體積小(xiao)、改善輸出波(bo)形、防(fang)止短路電(dian)(dian)流(liu)燒傷(shang)、不會(hui)出現恢復過電(dian)(dian)壓(ya)(ya)等(deng)優點。完全滿足GB50150-2006以及DL/T849.6-2004標(biao)準中各項指標(biao)的(de)要求。
工作中常見(jian)的解決方法:
1.變頻源主(zhu)機找不到諧振點。
原因:
1) 系統諧振點在主機(ji)的輸出頻(pin)率范圍之外;
2) 系統接線錯誤;
3) 系統未可靠接地;
4) 高壓采樣反饋信號(hao)開路或連(lian)接不(bu)可靠;
5) 試(shi)品有故障。
排除方法(fa):
1)檢查接(jie)(jie)地裝(zhuang)置可靠,接(jie)(jie)地連接(jie)(jie)線是否(fou)有(you)斷開點;
2)檢查(cha)勵磁變壓(ya)(ya)器的(de)高低壓(ya)(ya)線圈的(de)通斷;
3)檢查每一只電抗器的通斷;
4)檢(jian)查分(fen)壓器(qi)的信號線的通斷(duan);
5)檢查分壓(ya)器的(de)高(gao)低壓(ya)電容臂的(de)通斷(duan);
6)裝置自身升壓時沒有(you)諧振點,還需要(yao)檢(jian)查(cha)補(bu)償電(dian)容器(qi)的(de)通斷;
2.主機復位
原因(yin):
主機供電(dian)電(dian)源波動(dong);外(wai)界強磁(ci)場干擾(rao);主機未(wei)可靠接地;
3.裝(zhuang)置Q值偏低(di),即電壓(ya)升不上去,或(huo)升不高。
現象(xiang):
1)調諧曲(qu)線是一(yi)條曲(qu)線,有較(jiao)低的尖峰;
2)試驗時(shi)一(yi)次電壓(ya)較(jiao)高,高壓(ya)卻較(jiao)低,甚(shen)至在沒(mei)有升(sheng)到試驗電壓(ya)時(shi),一(yi)次電壓(ya)已經到達額定電壓(ya),回路自(zi)動降(jiang)壓(ya);
原因(yin):
1)電抗器與試(shi)品電容量不匹配(pei),沒有準(zhun)確找(zhao)到諧振點(dian);
2)試(shi)品損耗較高,系(xi)統Q值太低;
3)勵(li)磁變壓(ya)(ya)器高壓(ya)(ya)輸(shu)出電壓(ya)(ya)較低;
4)高(gao)壓(ya)(ya)連(lian)接(jie)線(xian)過長或沒有采用(yong)高(gao)壓(ya)(ya)放暈線(xian)。
排(pai)除方法:
1)將(jiang)補(bu)償電(dian)容(rong)器并接入(ru)試驗回路,加(jia)大回路電(dian)容(rong)量;
2)盡可(ke)能將多只電抗器串(chuan)聯,提(ti)高回(hui)路電感量;
3)提高勵磁變壓器的(de)輸出電壓;
4)干(gan)燥處理被試品(pin),提高被試品(pin)的(de)絕緣強度,減(jian)少回路的(de)有功損耗;
5)一(yi)般(ban)在設備較高電(dian)壓(ya)輸出時,采用高壓(ya)放暈(yun)線(xian),或將普通高壓(ya)輸出線(xian)改為較短的連(lian)線(xian),一(yi)般(ban)不超過5米(mi)。
4.電源跳閘(zha)
原因(yin):合閘瞬間(jian)電流過大;諧振系統回路短路。
排(pai)除方(fang)法:
1) 更換更大電流的空氣(qi)開(kai)關(或者短時(shi)脫開(kai)漏電保護)
串聯諧振試驗裝置是利用(yong)調(diao)(diao)諧(xie)電(dian)(dian)感與負荷(he)電(dian)(dian)容(rong)使(shi)之產生工頻(pin)串(chuan)聯(lian)諧(xie)振(zhen)(zhen),以獲得工頻(pin)試驗電(dian)(dian)壓(ya)(ya)(ya)的(de)串(chuan)聯(lian)諧(xie)振(zhen)(zhen)試驗裝(zhuang)置。串(chuan)聯(lian)諧(xie)振(zhen)(zhen)由隔離變壓(ya)(ya)(ya)器(qi)(qi)、調(diao)(diao)頻(pin)調(diao)(diao)壓(ya)(ya)(ya)電(dian)(dian)源、激(ji)勵(li)(li)變壓(ya)(ya)(ya)器(qi)(qi)、電(dian)(dian)抗器(qi)(qi)和電(dian)(dian)容(rong)分壓(ya)(ya)(ya)器(qi)(qi)組成。被試品(pin)的(de)電(dian)(dian)容(rong)與電(dian)(dian)抗器(qi)(qi)構成串(chuan)聯(lian)諧(xie)振(zhen)(zhen)連接方式(shi);分壓(ya)(ya)(ya)器(qi)(qi)并聯(lian)在被試品(pin)上,用(yong)于測量被試品(pin)上的(de)諧(xie)振(zhen)(zhen)電(dian)(dian)壓(ya)(ya)(ya),并作過壓(ya)(ya)(ya)保護(hu)信號;調(diao)(diao)頻(pin)功率輸出經激(ji)勵(li)(li)變壓(ya)(ya)(ya)器(qi)(qi)耦合給串(chuan)聯(lian)諧(xie)振(zhen)(zhen)回路,提供串(chuan)聯(lian)諧(xie)振(zhen)(zhen)的(de)激(ji)勵(li)(li)功率。
1、變頻(pin)源主機(ji)找不到諧振(zhen)點(dian)。
2、變頻源主機復位。
3、裝(zhuang)置(zhi)Q值偏低,即電壓升(sheng)不上(shang)去,或升(sheng)不高。
4、供(gong)電電源跳閘。
串聯諧振試驗裝置的構成及特點
串聯諧振試驗(yan)裝置(zhi)是運用串聯諧(xie)(xie)振(zhen)(zhen)原理,使回(hui)路產生(sheng)諧(xie)(xie)振(zhen)(zhen)電(dian)(dian)壓(ya)(ya)加(jia)到試(shi)品(pin)上,串聯諧(xie)(xie)振(zhen)(zhen)裝置目前(qian)分為變(bian)(bian)頻式和調感式兩(liang)大類。串聯諧(xie)(xie)振(zhen)(zhen)裝置主(zhu)要由變(bian)(bian)頻源(yuan)(變(bian)(bian)頻式)、高壓(ya)(ya)電(dian)(dian)抗器(qi)(qi)、可調式電(dian)(dian)抗器(qi)(qi)(調感式)、電(dian)(dian)容(rong)分壓(ya)(ya)器(qi)(qi)、激勵變(bian)(bian)壓(ya)(ya)器(qi)(qi)等(deng)幾部(bu)分組成。廣泛(fan)用于電(dian)(dian)力(li)(li)電(dian)(dian)纜、電(dian)(dian)力(li)(li)變(bian)(bian)壓(ya)(ya)器(qi)(qi)、水力(li)(li)發電(dian)(dian)機、GIS等(deng)大容(rong)量(liang),高電(dian)(dian)壓(ya)(ya)的(de)電(dian)(dian)容(rong)性(xing)試(shi)品(pin)的(de)交(jiao)接和預防(fang)性(xing)試(shi)驗!串聯諧(xie)(xie)振(zhen)(zhen)裝置具有需求電(dian)(dian)源(yuan)容(rong)量(liang)小(xiao)、設(she)備(bei)重量(liang)體積小(xiao)、改善輸出波(bo)形、防(fang)止短路電(dian)(dian)流(liu)燒傷(shang)、不會(hui)出現恢復過電(dian)(dian)壓(ya)(ya)等(deng)優點。完全滿足GB50150-2006以及DL/T849.6-2004標(biao)準中各項指標(biao)的(de)要求。
工作中常見(jian)的解決方法:
1.變頻源主(zhu)機找不到諧振點。
原因:
1) 系統諧振點在主機(ji)的輸出頻(pin)率范圍之外;
2) 系統接線錯誤;
3) 系統未可靠接地;
4) 高壓采樣反饋信號(hao)開路或連(lian)接不(bu)可靠;
5) 試(shi)品有故障。
排除方法(fa):
1)檢查接(jie)(jie)地裝(zhuang)置可靠,接(jie)(jie)地連接(jie)(jie)線是否(fou)有(you)斷開點;
2)檢查(cha)勵磁變壓(ya)(ya)器的(de)高低壓(ya)(ya)線圈的(de)通斷;
3)檢查每一只電抗器的通斷;
4)檢(jian)查分(fen)壓器(qi)的信號線的通斷(duan);
5)檢查分壓(ya)器的(de)高(gao)低壓(ya)電容臂的(de)通斷(duan);
6)裝置自身升壓時沒有(you)諧振點,還需要(yao)檢(jian)查(cha)補(bu)償電(dian)容器(qi)的(de)通斷;
2.主機復位
原因(yin):
主機供電(dian)電(dian)源波動(dong);外(wai)界強磁(ci)場干擾(rao);主機未(wei)可靠接地;
3.裝(zhuang)置Q值偏低(di),即電壓(ya)升不上去,或(huo)升不高。
現象(xiang):
1)調諧曲(qu)線是一(yi)條曲(qu)線,有較(jiao)低的尖峰;
2)試驗時(shi)一(yi)次電壓(ya)較(jiao)高,高壓(ya)卻較(jiao)低,甚(shen)至在沒(mei)有升(sheng)到試驗電壓(ya)時(shi),一(yi)次電壓(ya)已經到達額定電壓(ya),回路自(zi)動降(jiang)壓(ya);
原因(yin):
1)電抗器與試(shi)品電容量不匹配(pei),沒有準(zhun)確找(zhao)到諧振點(dian);
2)試(shi)品損耗較高,系(xi)統Q值太低;
3)勵(li)磁變壓(ya)(ya)器高壓(ya)(ya)輸(shu)出電壓(ya)(ya)較低;
4)高(gao)壓(ya)(ya)連(lian)接(jie)線(xian)過長或沒有采用(yong)高(gao)壓(ya)(ya)放暈線(xian)。
排(pai)除方法:
1)將(jiang)補(bu)償電(dian)容(rong)器并接入(ru)試驗回路,加(jia)大回路電(dian)容(rong)量;
2)盡可(ke)能將多只電抗器串(chuan)聯,提(ti)高回(hui)路電感量;
3)提高勵磁變壓器的(de)輸出電壓;
4)干(gan)燥處理被試品(pin),提高被試品(pin)的(de)絕緣強度,減(jian)少回路的(de)有功損耗;
5)一(yi)般(ban)在設備較高電(dian)壓(ya)輸出時,采用高壓(ya)放暈(yun)線(xian),或將普通高壓(ya)輸出線(xian)改為較短的連(lian)線(xian),一(yi)般(ban)不超過5米(mi)。
4.電源跳閘(zha)
原因(yin):合閘瞬間(jian)電流過大;諧振系統回路短路。
排(pai)除方(fang)法:
1) 更換更大電流的空氣(qi)開(kai)關(或者短時(shi)脫開(kai)漏電保護)
2) 檢查諧振系統回路是否(fou)短路。
尊敬的客戶: